• English
    • Latviešu
    • Deutsch
    • русский
  • Help
  • English 
    • English
    • Latviešu
    • Deutsch
    • русский
  • Login
View Item 
  •   DSpace Home
  • EK finansētie resursi / EC funded resources
  • Apvārsnis 2020 / Horizon 2020
  • Novel 1D photonic metal oxide nanostructures for early stage cancer detection (CanBioSe)
  • Konferenču krājumi (CanBioSe) / Conference Abstracts and Proceedings
  • View Item
  •   DSpace Home
  • EK finansētie resursi / EC funded resources
  • Apvārsnis 2020 / Horizon 2020
  • Novel 1D photonic metal oxide nanostructures for early stage cancer detection (CanBioSe)
  • Konferenču krājumi (CanBioSe) / Conference Abstracts and Proceedings
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Porous Aluminium Oxide Coating for the Development of Spectroscopic Ellipsometry Based Biosensor: Evaluation of Human Serum Albumin Adsorption

Thumbnail
View/Open
Article (1.374Mb)
Author
Maciulis, Vincentas
Malinovskis, Uldis
Erts, Donats
Ramanavicius, Arunas
Ramanaviciene, Almira
Balevicius, Saulius
Juciute, Silvija
Plikusiene, Ieva
Date
2020-10-23
Metadata
Show full item record
Abstract
An electrochemically synthesised porous anodic aluminium oxide (pAAO) layer has been analysed by means of spectroscopic ellipsometry. The determined thickness of the formed pAAO layer obtained from spectroscopic ellipsometry measurements and modelling was 322.75 ± 0.12 nm. The radius of the nanopores estimated from SEM images was 39 ± 5 nm and the distance between nanopores was 107 ± 6 nm. The investigation of human serum albumin (HSA) adsorption on the pAAO coating showed that: (i) the protein concentration inside nanopores, depending on exposure time, approximately was from 200 up to 600 times higher than that determined in buffer solution; (ii) the initial phase of the adsorption process is slow (3.23 mg·cm−3·min−1) in comparison with the protein desorption rate (21.2 mg·cm−3·min−1) by means of pAAO layer washing; (iii) conventional washing with PBS solution and deionised water does not completely remove HSA molecules from pAAO pores and, therefore, the HSA concentration inside nanopores after 16 h of washing still remains almost 100 times higher than that present in PBS solution. Thus, due to such binding ability, HSA can be successfully used for the blocking of the remaining free surface, which is applied for the reduction in non-specific binding after the immobilisation of biorecognition molecules on the pAAO surface. It was determined that some desorption of HSA molecules from the pAAO layer occurred during the sensor’s surface washing step; however, HSA concentration inside the nanopores still remained rather high. These results recommend the continued application of pAAO in the development of biosensors.
URI
https://dspace.lu.lv/dspace/handle/7/52889
DOI
https://doi.org/10.3390/coatings10111018
Collections
  • Konferenču krājumi (CanBioSe) / Conference Abstracts and Proceedings [7]

University of Latvia
Contact Us | Send Feedback
Theme by 
@mire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

View Usage Statistics

University of Latvia
Contact Us | Send Feedback
Theme by 
@mire NV