• English
    • Latviešu
    • Deutsch
    • русский
  • Help
  • English 
    • English
    • Latviešu
    • Deutsch
    • русский
  • Login
View Item 
  •   DSpace Home
  • B4 – LU fakultātes / Faculties of the UL
  • A -- Medicīnas un dzīvības zinātņu fakultāte / Faculty of Medicine and Life Sciences
  • Raksti (MDZF) / Articles
  • View Item
  •   DSpace Home
  • B4 – LU fakultātes / Faculties of the UL
  • A -- Medicīnas un dzīvības zinātņu fakultāte / Faculty of Medicine and Life Sciences
  • Raksti (MDZF) / Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Non-contact breath sampling for sensor-based breath analysis

Thumbnail
View/Open
Article (1.221Mb)
Author
Mochalski, Pawel
Shuster, Gregory
Leja, Marcis
Unterkofler, Karl
Jaeschke, Carsten
Roberts, Skapars
Gasenko, Evita
Polaka, Inese
Vasiljevs, Edgars
Shani, Gidi
Mitrovics, Jan
Mayhew, Christopher A
Haick, Hossam
Date
2019
Metadata
Show full item record
Abstract
Breath analysis holds great promise for real-time and non-invasive medical diagnosis. Thus, there is a considerable need for simple-in-use and portable analyzers for rapid detection of breath indicators for different diseases in their early stages. Sensor technology meets all of these demands. However, miniaturized breath analyzers require adequate breath sampling methods. In this context, we propose non-contact sampling; namely the collection of breath samples by exhalation from a distance into a miniaturized collector without bringing the mouth into direct contact with the analyzing device. To evaluate this approach different breathing maneuvers have been tested in a real-time regime on a cohort of 23 volunteers using proton transfer reaction mass spectrometry. The breathing maneuvers embraced distinct depths of respiration, exhalation manners, size of the mouth opening and different sampling distances. Two inhalation modes(normal, relaxed breathing and deep breathing) and two exhalation manners(via smaller and wider lips opening)forming four sampling scenarios were selected. A sampling distance of approximately 2 cm was found to be a reasonable trade-off between sample dilution and requirement of no physical contact of the subject with the analyzer. All four scenarios exhibited comparable measurement reproducibility spread of around 10%. For normal, relaxed inspiration both dead-space and end-tidal phases of exhalation lasted approximately 1.5 s for both expiration protocols. Deep inhalation prolongs the end-tidal phase to about 3 s in the case of blowing via a small lips opening, and by 50% when the air is exhaled via a wide one. In conclusion, non-contact breath sampling can be considered as a promising alternative to the existing breath sampling methods, being relatively close to natural spontaneous breathing. --///-- This work is licensed under a CC BY 4.0 license.
URI
https://dspace.lu.lv/dspace/handle/7/54367
DOI
10.1088/1752-7163/ab0b8d
Collections
  • Raksti (MDZF) / Articles [49]

University of Latvia
Contact Us | Send Feedback
Theme by 
@mire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

View Usage Statistics

University of Latvia
Contact Us | Send Feedback
Theme by 
@mire NV