dc.contributor.advisor | Kalniča-Dorošenko, Kristīne | |
dc.contributor.author | Ismaeel, Maryam Abdulghani Mohamed Sadeq | |
dc.contributor.other | Latvijas Universitāte. Fizikas, matemātikas un optometrijas fakultāte | |
dc.date.accessioned | 2021-07-02T01:06:06Z | |
dc.date.available | 2021-07-02T01:06:06Z | |
dc.date.issued | 2021 | |
dc.identifier.other | 82210 | |
dc.identifier.uri | https://dspace.lu.lv/dspace/handle/7/55902 | |
dc.description.abstract | Darba mērķis bija izpētīt 18 samazinātas kvalitātes spraugas lampas attēlu, kuros attēloti acu priekšējo daļu struktūras, ietekmi uz 5 profesionāļu atzinumiem. Attēli, kas sadalīti 3 6 attēlu komplektos trim samazināšanas filtriem, izplūdums (1-6), troksnis (7-12) un kontrasts (13-18), tika parādīti datora ekrānā un salīdzināti ar oriģinālajiem attēliem. Rezultāti tika saskaņoti ar īsto attēla diagnozi un novērtēti 3 punktu sistēmā, pareizs atradums: 1 un 0,5 (daļēji) punkti, nepareizs vai nav atrasts: 0 punkti. Tika reģistrēti 53 punkti no 90 (58% pareizi un 41% nepareizi). Rezultāti liecina, ka attēla kvalitātes samazināšana būtiski neietekmēja atradumus (jutīgums 97,78). Tomēr vislielāko ietekmi uz konstatējumiem atstāja izplūdums (57 %) un liela gaismas intensitāte (43 %). Attēla kvalitātes vērtējumu ietekmē arī subjektīvā vērtēšana un fotografēšanas prasmes. | |
dc.description.abstract | The aim was to investigate the impact of 18 reduced quality slit-lamp images showing abnormal anterior eye structures on the findings of 5 professionals. Images were divided into 3 sets of 6 images for three reduction filters, blur (1-6), noise (7-12), and contrast (13-18). Images were evaluated on a computer screen and compared with original images. Findings were matched with true image diagnosis in scores of 3 points, 1 and 0.5 (partial) points for correct findings, and 0 points for incorrect or no findings. A total of 53 points from 90 was recorded (58 % correct, 41 % incorrect). Reduction of image quality did not significantly impact findings (97.78 sensitivity). However, blur (57 %) and high light levels (43 %) effects impacted findings. Evaluation of image quality is also impacted by subjective evaluation and capturing skill. | |
dc.language.iso | lav | |
dc.publisher | Latvijas Universitāte | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Optometrija | |
dc.subject | telehealth | |
dc.subject | teleophthalmology | |
dc.subject | anterior eye structures | |
dc.subject | reduced quality images | |
dc.subject | remote examination | |
dc.title | Attēla kvalitātes ietekme uz acs struktūru izvērtēšanu foto-diagnostikā | |
dc.title.alternative | The Effect of Image Quality on the Evaluation of Eye Structures in the Photo-Diagnostics | |
dc.type | info:eu-repo/semantics/bachelorThesis | |