dc.contributor.advisor | Ikaunieks, Gatis | |
dc.contributor.author | Kalnupa, Marika | |
dc.contributor.other | Latvijas Universitāte. Fizikas, matemātikas un optometrijas fakultāte | |
dc.date.accessioned | 2023-09-05T01:05:44Z | |
dc.date.available | 2023-09-05T01:05:44Z | |
dc.date.issued | 2023 | |
dc.identifier.other | 95709 | |
dc.identifier.uri | https://dspace.lu.lv/dspace/handle/7/63442 | |
dc.description.abstract | Darbs ir uzrakstīts latviešu valodā uz 28 lapaspusēm, satur 12 attēlus, 7 tabulas, 28 literatūras avotu atsauces. Maģistra darba mērķis novērtēt uzlabotas aditīva aprēķina metodes precizitāti un potenciālo pielietojumu presbiopijas korekcijas noteikšanā. Pētījuma dalībniekiem tika noteikts redzes asums tuvumā ar tāluma korekciju un, izmantojot plus-build-up kā kontrolmetodi, tika noteikts nepieciešamais aditīva stiprums 40 cm attālumā. Iegūtie rezultāti parādīja, ka aprēķina formula ir pietiekoši precīza, lai to izmantotu arī ikdienā, veicot redzes pārbaudes. Apstiprinājās darbā izvirzītā hipotēze, ka, novērtējot aditīva lielumu ar plus-build-up metodi un salīdzinot iegūto rezultātu ar aprēķina formulu un jau esošo vadlīniju, aditīva aprēķina formulas iegūtais rezultāts būs tuvāks pacientam nepieciešamajam tuvuma aditīvam. | |
dc.description.abstract | Master's thesis is written in Latvian on 28 pages, contains 12 pictures, 7 tables, 28 references to literary sources. The aim of the Master's thesis is to assess the accuracy and potential application of the improved additive calculation method in determining presbyopia correction. The participants of the study were determined near visual acuity with distance correction and, using plus-build-up as a control method, the required strength of the additive at a distance of 40 cm was determined. The obtained results showed that the calculation formula is accurate enough to be used also in daily vision tests. The hypothesis put forward in the work was confirmed, that when assessing the size of the additive with the plus-build-up method and comparing the obtained result with the calculation formula and the already existing guidelines, the result of the additive calculation formula will be closer to the proximity additive required by the patient. | |
dc.language.iso | lav | |
dc.publisher | Latvijas Universitāte | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Klīniskā optometrija | |
dc.subject | aditīvs | |
dc.subject | presbiopija | |
dc.subject | aprēķina metode | |
dc.subject | attālinātās redzes pārbaudes | |
dc.subject | klasiskā plus-build-up metode | |
dc.title | Klīniskās plus-built-up un aprēķina metožu salīdzinājums presbiopijas korekcijas novērtēšanā | |
dc.title.alternative | The Comparison of Clinical “Plus-Build-up” and Calculation Methods for Presbyopia Correction | |
dc.type | info:eu-repo/semantics/masterThesis | |