Show simple item record

dc.contributor.advisorMozers, Artūrs
dc.contributor.authorNikolajevs, Antons
dc.contributor.otherLatvijas Universitāte. Fizikas, matemātikas un optometrijas fakultāte
dc.date.accessioned2023-09-06T01:04:07Z
dc.date.available2023-09-06T01:04:07Z
dc.date.issued2023
dc.identifier.other96885
dc.identifier.urihttps://dspace.lu.lv/dspace/handle/7/64373
dc.description.abstractDarbā tika izveidota eksperimentāla iekārta mangeto-optisko absorbcijas signālu iegūšanai cēzija atomu tvaikos. Tā kā signālus var ietekmēt daudzi eksperimentālie faktori, tika uzņemti signāli pie dažādiem parametriem - lāzera frekvences, pumpējošā stara intensitātes, pumpējošā stara diametra -, lai noskaidrotu to ietekmi uz signāliem. Iegūtie signāli tika salīdzināti ar skaitliski modelētiem signāliem. Tika noskaidrots, ka vislielākā signālu amplitūda ir pie Fg = 4 → Fe = 3 supersīkstruktūras pārejas, savukārt vismazākā amplitūda ir pie Fg = 3 → Fe = 4 pārejas. Tika novērots, ka, palielinot pumpējošā stara intensitāti, signāli kļūst asimetriski, savukārt pie mazākas intensitātes tiek novērota zondējošā stara ietekme uz signāliem. Palielinot pumpējošā stara diametru, signālu amplitūda arī palielinās.
dc.description.abstractIn this study an experimental setup was built to obtain omagneto-optical absorption signals in caesium atomic vapour. Since the signals can be influenced by various experimental factors, signals were recorded at different parameters such as laser frequency, pump beam intensity, and pump beam diameter to investigate their effects on the signals. The obtained signals were compared with numerically modeled signals. It was found that the highest signal amplitude occurs at the Fg = 4 → Fe = 3 hyperfine transition, while the lowest amplitude is observed at the Fg = 3 → Fe = 4 transition. It was observed that increasing the pump beam intensity leads to asymmetric signals, whereas at lower intensity, the probing beam’s effect on the signals becomes significant. Increasing the pump beam diameter results in an increased signal amplitude.
dc.language.isolav
dc.publisherLatvijas Universitāte
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectFizika
dc.subjectcēzijs
dc.subjectBloha vienādojumi
dc.subjectmagnētiskais lauks
dc.subjectabsorbcija
dc.titleEksperimentālo parametru ietekme uz magneto-optiskiem absorbcijas signāliem cēzija atomu tvaikos
dc.title.alternativeInfluence of experimental parameters on magneto-optical absorption signals in caesium atomic vapour
dc.typeinfo:eu-repo/semantics/bachelorThesis


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record