dc.description.abstractMaģistra darbs ir uzrakstīts latviešu valodā uz 38 lapaspusēm. Tas satur 14 attēlus, 3 tabulas, 37 atsauces uz literatūras avotiem un 2 pielikumus. Maģistra darba mērķis bija novērtēt stereoredzes toleranci pret inducēto anizeikoniju. Pētījumā piedalījās 27 dalībnieki (vidējais vecums 32 ± 14 gadi). Eksperimentā mākslīgi tika inducēta anizeikonija ar afokālu izeikonisko lēcu ar 7,9 % palielinājumu, tika mērīti un salīdzināti stereoredzes rezultāti, salīdzinot tos ar TNO un datorizēto stereoredzes testu, kā arī tika novērtētas anizeikonijas lieluma izmaiņas pirms un pēc tās inducēšanas. Mērījumu veikšanai anizeikonija tika novērtēta 100 cm attālumā ar datorizēto (online) anizeikonijas testu pēc Aniseikonia Inspector 1. versijas un NAT testa principa. Stereoredze tika novērtēta 100 cm attālumā ar datorizēto stereoredzes testu un 40 cm attāluma ar TNO testu. Rezultāti parādīja, ka tika konstatētas būtiski sliktāka stereoredze pēc anizeikonijas inducēšanas ar izeikonisko lēcu. Līdz ar to var secināt, ka afokāla izeikoniskā lēca ar 7,9 % palielinājumu statistiski nozīmīgi pasliktina stereoredzi TNO un datorizētajā stereoredzes testā.
dc.description.abstractMaster’s thesis is written in Latvian language on 38 pages. It contains 14 figures 3 table, 37 references and 2 appendices. The aim of the master's thesis was to evaluate stereopsis tolerance to induced aniseikonia. The study involved 27 participants (mean age 32 ± 14 years). Aniseikonia was artificially induced in the experiment using an afocal iseikonic lens with a 7,9 % magnification, and stereopsis results were measured and compared, contrasting them with TNO and computerized stereopsis tests, while also assessing changes in aniseikonia magnitude before and after its induction. Aniseikonia measurement was performed at a distance of 100 cm using the computerized (online) Aniseikonia Inspector 1.0 version and NAT test principle. Stereopsis was evaluated at a distance of 100 cm using computerized stereopsis test and at 40 cm using the TNO test. The results show that significant changes in stereopsis measurements were found after induction of aniseikonia with the iseikonic lens. Therefore, it can be concluded that an afocal iseikonic lens with 7,9 % magnification statistically significantly impairs stereopsis in TNO and computerized stereopsis tests.
dc.language.isolav
dc.publisherLatvijas Universitāte
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectKlīniskā optometrija
dc.subjectizeikoniskas lēcas
dc.subjectbinokulāra redze
dc.subjectstereoredze
dc.subjectanizeikonija
dc.titleInducētas anizeikonijas ietekme uz stereoredzi
dc.title.alternativeThe Effect of Induced Aniseikonia on Stereoacuity